DESCRIPTION: TLM series filters are especially designed to be suitable for stationary and mobil applications. Suction, inline and return assembly with inlet and outlet port in "L" configuration (Sx. or Dx.) Port sizes: 3/8"÷1 1 /2" BSP-NPT - Flow rates: 4÷600 L/min.
-------------------------------------------------------------------------------------
TECHNICAL DATA
Max. working pressure: 2.000 kPa (20 bar)
Max. test pressure: 4.000 kPa (40 bar)
Burst pressure: 6.000 kPa (60 bar)
Fatigue test: 0÷1.000 kPa (0÷10 bar) / 300.000 cycles
Head: aluminium
Bowl: cold formed steel
Working temperature: -25÷+110°C
FILTER ELEMENTS WITH BY-PASS Delta p 170 kPa (1,7 bar) ± 0,2
Inorganic fibres: 10µ - 25µ Abs.
Paper: 10µ - 25µ
Steel wire mesh: 60µ - 125µ
Special execution on request.
FILTER ELEMENTS COLLAPSE PRESSURES
Standard: Delta p 500 kPa (5 bar) all types
SEALS Standard: Buna-N - On request: FKM - Fluoroelastomer |
|
|