They are normally installed downstream from the pump. They can be secured without pipes directly on the machines to be protected by the pollution. The filter elements used provide an high filtration efficiency and a positive protection to sensitive components.
------------------------------------------------------------------------------------
TECHNICAL DATA
Max. working pressure: 25.000 kPa (250 bar)
Max. testing pressure: 50.000 kPa (500 bar)
Burst pressure: 75.000 kPa (750 bar)
Fatigue test: 0 ÷ 25.000 kPa (0 ÷ 250 bar) / 1.000.000 cicli
Head: S.G. iron cast - Bowl: forged steel
Working temperature: -25 ÷ +110°C
By-pass valves: Standard Delta p 350 ÷ 600 kPa (3,5 ÷ 6 bar)
FILTER ELEMENTS
Inorganic fibres: 3µ - 6µ - 12µ - 25µ Abs.
Special paper: 10µ - 25µ
Wire mesh: 10µ - 25µ - 30µ - 60µ
Special execution on request.
FILTER ELEMENT COLLAPSE PRESSURE:
Delta p 2.100 kPa (21 bar) tutti i tipi
Delta p 21.000 kPa (210 bar) FT-FC-FD-FV-RD-RV-RT-MS
SEALS: Standard: Buna-N - On request: FKM - Fluoroelastomer |
|
|