DESCRIPTION: The KTS Series filter is designed for use in close loop hydrostatic transmissions. The oil returning from the pilot line as well as the drain of the primary transmission enters the filter through the port R
and passes through the filter element. The filtered oil exits through the S port and feeds the transmission boost pump inlet. A system of bypass valves safeguards the mechanical structure of the filter from possible pressure or overflow peaks and sets the maximum pressure value on the boost pump inlet.
------------------------------------------------------------------------------------
TECHNICAL DATA
Max. working pressure: .000 kPa (10 bar)
Max. test pressure: 1.500 kPa (15 bar)
Burst pressure: 30.000 kPa (30 bar)
Fatigue test: 0÷1000 kPa (0÷10 bar) / 300.000 cycles
Head: Aluminium alloy
Bowl: Steel
Working temperature: -25÷+110°C
By pass valve: Delta p 250 kPa (2,5 bar) return
Delta p 50 kPa (0,5 bar) suction
FILTER ELEMENTS
Inorganic fibres: 3µ - 6µ - 12µ - 25µ Abs.
Special paper: 10µ - 25µ
Special paper reinforced with metal screen: 10µ - 25µ
Wire mesh: 30µ - 60µ - 125µ
FILTER ELEMENTS COLLAPSE PRESSURES
Standard: Delta p 1.000 kPa (10 bar)
SEALS Standard: Buna-N On request: FKM - Fluoroelastomer
|
|
|